System Service Mode
SM Appendix 3-49 D115/D116
Appendix:
SP Mode
Tables
093
CERT: St ExpTime
Displays the start time of the period for which the current @Remote
certification is enabled.
094
CERT: End ExpTime
Displays the end time of the period for which the current @Remote
certification is enabled.
150
Ins Country
Select from the list the name of the country where embedded RCG-M is
installed in the machine. After selecting the country, you must also set the
following SP codes for embedded RCG-M:
SP5816-153
SP5816-154
SP5816-161
0: Japan, 1: USA, 2: Canada, 3: UK, 4: Germany, 5: France
6: Italy, 7: Netherlands, 8: Belgium, 9: Luxembourg, 10: Spain
151
Aut Line Detect
Press [Execute].
Setting this SP classifies the telephone line where embedded RCG-M is
connected as either dial-up or push type, so embedded RCG-M can
automatically distinguish the number that connects to the outside line.
The current progress, success, or failure of this execution can be
displayed with SP5816 152.
If the execution succeeded, SP5816 153 will display the result for
confirmation and SP5816 154 will display the telephone number for the
connection to the outside line.