SP5xxx: Mode
D017/D018/D019/D020 5-116 SM
12 StapleStd2
13 StapleStd3 Not Used
14 StapleStd4
21 StapleBnd1
22 StapleBnd2
23 StapleBnd3
GWWS Analysis DFU
5842
This is a debugging tool. It sets the debugging output mode of each Net File
process
5844 USB
Transfer Rate
1
Sets the speed for USB data transmission.
[Full Speed]
[Auto Change]
Vendor ID
2
Sets the vendor ID:
Initial Setting: 0x05A Ricoh Company
[0x0000 to 0xFFFF/1] DFU
Product ID
3
Sets the product ID.
[0x0000 to 0xFFFF/1] DFU
Device Release No.
4
Sets the device release number of the BCD (binary coded decimal) display.
[0000 to 9999/1] DFU
Enter as a decimal number. NCS converts the number to hexadecimal