SERVICE PROGRAM MODE
B089/B093 4-8 SM
1105* Fusing Temperature Adjustment
1105 1 Roller Center
1105 2 Roller Ends
Adjusts the fusing temperature at the center and
both ends of the hot roller for normal printing.
[120 ~ 200 / 165 / 1°C/step]
1105 3 Energy Saver Adjusts the fusing temperature at the center and
both ends of the hot roller for energy saver mode.
[0 ~ 160 / 150 / 1°C/step]
1105 4 Thick Paper - Center
1105 5 Thick Paper - Ends
Adjusts the additional fusing temperature for thick
paper for the 2nd paper tray and for the bypass tray.
[0 ~ 30 / 15 / 1°C/step]
1105 6 After Warming-up - Center Adjusts the fusing temperature at the center of the
hot roller after the machine has warmed up.
[120 ~ 200 / 165 / 1°C/step]
1105 7 After Warming-up - Ends Adjusts the fusing temperature at both ends of the
hot roller after the machine has warmed up.
[120 ~ 200 / 175 / 1°C/step]
1105 8 After Warming-up - No. of
Pages
In this machine, fusing temperature is kept 10°C
higher than the normal temperature for a number of
pages after the machine has warmed up. This SP
selects the number of pages made at this
temperature. See Detailed Section Descriptions –
Fusing for more details.
[0 ~ 10 / 3 / 1 page/step]
1105 9 After Warming-up - Times
In this machine, fusing temperature is kept 10°C
higher than the normal temperature for a short while
after the machine been warmed up. This SP selects
the length of time that this temperature is used. See
Detailed Section Descriptions – Fusing for more
details.
[0 ~ 180 / 60 / 1s/step]
1106 Fusing Temp. Display
1106 1 Roller Center
1106 2 Roller Ends
Displays the fusing temperature for the center or
both ends of the hot roller.
1106 3 In the Machine at Power On Displays the temperature in the machine at power
on.
This temperature is monitored by the thermistor on
the SBCU board.
Fusing Soft Start Setting 1108*
Selects whether the fusing temperature control cycle is 1 or 3 seconds.
If this is “1 (3 s)”, the power supply fluctuation caused by the fusing lamp turning
on is less often.
[0 = 1 s / 1 = 3 s]
Default: 0 = N. America, 1 = Europe/Asia
Fusing Nip Band Check 1109
Checks the fusing nip band (! 4.2.11)
[1 = Start / 0 = Stop]