SERVICE PROGRAM MODE
SM 4-41 B089/B093
Service
Tables
5816* Remote Service
5816 1 I/F Setting Switches the remote diagnostics function off and
on.
[0~2 / 2 / 1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
5816 2 CE Call Allows the customer engineer to start or end the
remote machine check using CSS or NRS by
pressing the center report key.
5816 3 Function Flag Enables and disables remote diagnosis via the
NRS network.
[0~1 / 0 / 1]
0: Disables remote diagnosis via network.
1: Enables remote diagnosis via network.
5816 4 Communication Test Call Executes a transmission test call for NRS. The test
returns a value in the range 0 to 99.
0: Normal end (center operating)
1: Normal end (center not operating)
Other: Abnormal
5816 5 Device Information Call Executes a call to determine whether the machine
is operating. The test returns a value in the range 0
to 99.
0: Normal end (center operating)
1: Normal end (center not operating)
Other: Abnormal
5816 6 Device Information Call
Display
Determines whether the item for initial setting of
the screen for the NRS device information
notification call is displayed.
0: Enabled. Item initial setting not displayed.
1: Disable. Item for initial setting is displayed.
5816 7 SSL Disable Determines whether RCG (Remote
Communication Gate) confirmation is done by SSL
during an RCG send for the NRS via a network
interface.
0: Yes. SSL not used.
1: No. SSL used.
5816 8 RCG Connect Timeout Sets the length of time (seconds) for the timeout
when the RCG (Remote Communication Gate)
connects during a call via the NRS network.
[1~90 / 10 / 1 sec.]
5816 9 RCG Write to Timeout Sets the length of time (seconds) for the timeout
when send data is written to the RCG during a call
via the NRS network.
[0~100 / 30 / 1 sec.]
5816 10 RCG Read Timeout Sets the length of time (seconds) for the timeout
when send data is written from the RCG during a
call via the NRS network.
[0~100 / 30 / 1 sec.]