SERVICE RAM ADDRESSES
SM 3-75 B576
Fax Option
B576
680340 to 680342(H) - PSTN-1 line settings
680340
Bits 0 and 1: PSTN access method from behind a PABX.
Bit 1 0 Setting
0 0 Loop start
0 1 Ground start
1 0 Flash start
1 1 Not used
Bit 2: Telephone line type.
0: PSTN, 1: PABX
Bits 3 and 4: Dialing type.
Bit 4 3 Setting
0 0 Pulse dialing
0 1 Not used
1 0 Tone dialing
1 1 Not used
Bits 4 to 7: Not used
680341: PSTN access number for loop start
Access number Hex value to program (BCD)
0 F0
# #
9 F9
00 00
# #
99 99
680342
Bit 0: Transmission disabled
0: Tx and Rx, 1: Rx only
Bit 1: Memory Lock reception
0: Enabled, 1: Disabled
Bits 2 to 7: Not used
680348 to 68034A(H) - PSTN-2 line settings
680360(H) – Polling ID Code (Low – Hex)
680361(H) – Polling ID Code (High – Hex)
680362(H) - Confidential ID (low - BCD)
680363(H) - Confidential ID (high - BCD)
680364(H) - Memory Lock ID (low - BCD)
680365(H) - Memory Lock ID (high - BCD)