SERVICE CALL CONDITIONS
B132/B200 4-34 SM
FGATE error 1: Feedback remains HIGH for C write
SC236 D
After the start of timing to create
the cyan image, the PFGATE
register of the GAVD does not
assert, even after 5 sec. when:
• Images are created on the
drum.
• MUSIC patterns are created
on the transfer belt.
The BICU received no feedback
(LOW signal) from the LD unit to
indicate that the lasers started
firing at the prescribed time to
create the patterns.
• GAVD on the BICU defective
• PCI I/F on the IPU defective
• ASIC on the IOB defective
• Controller board disconnected, defective
• Harness between the BICU and LDB unit
disconnected, loose, or defective.
• Check board connections, replace
FGATE error 1: Feedback remains LOW for C write
SC237
After the start of timing to create
the cyan image, the PFGATE
register of the GAVD does not
assert, even after 5 sec. when:
• Images are created on the
drum.
• MUSIC patterns are created
on the transfer belt.
The BICU received a LOW
feedback signal, but the signal
remained LOW (indicating the
lasers were still operating), even
after creation of the next image
should have started.
• GAVD on the BICU defective
• PCI I/F on the IPU defective
• ASIC on the IOB defective
• Check board connections, replace
SC240 C
LD error 1: K
SC241 C
LD error 1: Y
SC242 C
LD error 1: M
SC243 C
LD error 1: C
An error is asserted at the LD
error terminal of the black,
yellow, magenta, or cyan LD
driver after initialization of the LD
because the power to the LD
was higher or lower than the
prescribed limit.
• LD defective due to wear, damage, short
circuit
• LDB harness disconnected, loose or
defective