SERVICE CALL CONDITIONS
B132/B200 4-44 SM
Separation power pack output error
SC460 D
An interrupt checks the status of
the power pack every 2 ms. This
SC is issued if the BCU detects
a short in the power pack 250
times at D(ac) within 500 ms.
Damaged insulation on the high-voltage
supply cable
Damaged insulation around the high-
voltage power supply.
1. Replace the high-voltage supply cable.
2. Replace the high-voltage power supply unit.
3. Replace the IOB.
Waste toner bottle full
SC484 D
The toner full sensor goes HIGH
for more than 500 ms, indicating
that the waste toner bottle is full.
Remove waste toner bottle, empty it
Waste toner bottle motor error
SC485 D
The lock signal of the waste
toner bottle motor remains HIGH
for more than 600 ms.
Waste toner bottle motor defective
Waste toner bottle set error
SC487 D
The set sensor of the waste
toner bottle remains LOW for
more than 500 ms. (The sensor
goes HIGH when the bottle is
installed correctly.)
Install the waste toner bottle
Remove waste toner bottle and reinstall
correctly
Waste toner transport lock
SC488 D
Waste toner cannot be
transported to the waste toner
bottle.
Blockage in the line to the waste toner
bottle
Peltier Unit error
SC490 C
The Abnormal Condition signal
for the Peltier Unit is received 10
times.
Peltier Unit is defective