SERVICE CALL CONDITIONS
B132/B200 4-70 SM
SC900: Miscellaneous
Electrical total counter error
SC900 D
The total counter contains
something that is not a number.
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
SC910
External controller error 1
SC911
External controller error 2
SC912
External controller error 3
SC913
External controller error 4
B
The external controller (Fiery) sends
an error message.
Turn the machine power
off/on
External controller error 5
SC914 B
The external controller (Fiery) sends
an error message.
Turn the machine power off/on
External controller down
SC919 D
The EAC received an interrupt signal
from the FLUTE serial driver during
print jobs in progress and the
connection between the copier and
external controller was broken.
Note: The EAC is the External Api
Converter.
Switch the machine off and on.
Printer error 1
SC920 B
An internal application error was
detected and operation cannot
continue.
Software defective; turn the machine
off/on, or change the controller firmware
Insufficient memory
Printer error 2
SC921 B
When the application started, the
necessary font was not on the SD
card.
Font not on the SC card