SERVICE PROGRAM TABLES
B132/B200 5-26 SM
1106 Fusing Temp Disp Fusing Lamp Control Method/Temperature Display
These SP codes control the temperature control of the hot roller and display the
temperatures of the hot roller, pressure roller, heating roller, and heating roller
lamps.
001 Temp Ctrl On/Off Hot roller fusing lamp control switch
0: OFF, 1: PID
002 Phase Ctrl On/Off Hot roller phase control
0:OFF 1:ON
003 Htg Roll Ctr Temp
Displays the temperature in centigrade of the fusing lamp
(center) in the heating roller. Range: 0 to 230
004 Htg Roll End Temp
Displays the temperature in centigrade of the fusing lamp
(ends) in the heating roller. Range: 0 to 230
005 Press Roll Temp
Displays the temperature in centigrade of the pressure
roller. Range: 0 to 230
006 Hot Roll Temp
Displays the temperature in centigrade of the hot roller.
Range: 0 to 230
1107 Mode Shift Setting Mode Shift Setting
Mode Shift Mode Shift Setting
001 Low Temp SW
The calculated value for the specified temperatures when
the readings of the environmental sensors are low.
[0~20/1 deg.]
002 High Temp SW
The calculated value for the specified temperatures when
the readings of the environmental sensors are high.
[-20~0/1 deg.]
003 Pres Roll Reload Press Roll Reload
004 Idle Temp On/Off
The hot roller temperature that determines whether the
fusing unit rollers are rotated freely during warmup.
[80~200/1 deg.]
005 Idle Time:Extend
The length of time the fusing/exit motor remains on after
the fusing unit has reached the warmup temperature.
[0~10/1 min.]
006 Feed Norm Temp
Determines whether fusing exit motor remains before
feeding plain paper after warmup temperature for the
heating roller has been reached.
0: No 1: Yes
007 Press Temp:Norm
The temperature calculated for the specified temperature
when the fusing/exit motor starts to rotate when plain
paper starts to feed.
[0~20/1 deg.]
008 Press Time:Norm
The time calculated to be added to the rotation time of the
fusing/exit motor at the start of plain paper feed, based on
the temperature specified temperature.
009 Fuse Exit M Cycles The cycles of the fusing/exit motor at standby.
[10~240/1 min. ]
010 Fuse Exit M Rot The time the fusing exit motor rotates at standby.
[0~1/1 ]