SERVICE PROGRAM TABLES
SM 5-73 B132/B200
Service Tables
2841 Sp2:FC:LL Special Paper 2: FC Low
2842 Sp2:FC:ML Special Paper 2: FC Medium Low
2843 Sp2:FC:MM Special Paper 2: FC Medium
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum to ITB, 2) create bias for image transfer
from ITB to paper (PTR), and 3) neutralize the charges on the both sides of the
paper to separate the paper from the ITB (SepDC, SepAC). These settings are
used when printing on Special Paper 2 in the full-color mode and are applied only to
the image area.
2841 2842 2843
017 Side1:PTR [10~250/5%] [10~250/5%] [10~250/5%]
018 Side1:SepDC
019 Side1:SepAC
027 Side2:PTR
028 Side2:SepDC
029 Side2:SepAC
2844 Sp2:FC:MH Special Paper 2: FC Medium High
2845 Sp2:FC:HH Special Paper 2: FC High
2844 2845
017 Side1:PTR [10~250/5%] [10~250/5%]
018 Side1:SepDC [10~250/5%]
019 Side1:SepAC [10~250/5%] [10~250/5%]
027 Side2:PTR [10~250/5%]
028 Side2:SepDC
029 Side2:SepAC
2851 Sp3 K Bias Set Bias for Special Paper 3: K
These SPs set the standard values of the electrical charges that are applied to 1)
create bias for image transfer from drum to ITB, 2) create bias for image transfer
from ITB to paper (PTR), and 3) neutralize the charges on the both sides of the
paper to separate the paper from the ITB (SepDC, SepAC). These settings are
used when printing on Special Paper 3 in the black-and-white mode and are applied
only to the image area.
001 ITB
[0~500/0.1 µa]
007 Side1:PTR
[-100~0/1 µa]
008 Side1:SepDC
[0~100/0.1 µa]
009 Side1:SepAC [80~120/0.1 kV]
012 Side2:PTR
[-100~0/1 µa]
013 Side2:SepDC
[0~100/0.1 µa]
014 Side2:SepAC [80~120/0.1 kV]