SERVICE PROGRAM TABLES
B132/B200 5-92 SM
3577 Chrg AC Control Display Value for Control of Development AC
Displays the ac bias that was referenced during processing control and used in the
previous jobs. (Process control is set for Auto with SP3501 001.)
001 Std Spd:K
002 Std Spd:M
003 Std Spd:C
004 Std Spd:Y
[0~300/0 kV]
Std Spd (normal speed): 52 to 128 g/m
2
006 Low Spd:K
007 Low Spd:M
008 Low Spd:C
009 Low Spd:Y
[0~300/0 kV]
Low Spd (half-speed): Paper weight 128 o 256 g/m
2
3581 LD Power Control Display Value for Control of LD Power
Displays the LD power that was referenced during processing control and used in
the previous jobs. (Process control is set for Auto with SP3501 001.)
001 Std Spd:K
002 Std Spd:M
003 Std Spd:C
004 Std Spd:Y
[-117~127/1]
Std Spd (normal speed): 52 to 128 g/m
2
006 Low Spd:K
007 Low Spd:M
008 Low Spd:C
009 Low Spd:Y
[-117~127/1]
Low Spd (half-speed): Paper weight 128 o 256 g/m
2
3605 Factory Files Set Up Developer DFU
3701 Small Img Mode Set Small Image Mode
This feature is not presently not used in process control (March 2005)
[0~1/1]