SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103 4-20 SM
Charge Corona Error 2: Grid Leak
SC304 B
A high feedback voltage (H) for
the charge corona 60 ms. Also,
during this time, the voltage of
the charge grid remained less
than –400V
Cycle the machine off/on
Charge unit set incorrectly (not locked in
place)
Charge unit connector loose, broken,
defective
Charge Corona Wire Cleaner Error 1
SC305 C
One of these occurred after the charge
corona cleaner motor was switched on:
The charge corona wire cleaner motor
remained locked within 10 sec after the
motor switched on.
The charge corona wire cleaner motor
failed to lock within 45 s after the start of
cleaning.
Cycle the machine off/on
Charge corona wire cleaner
motor defective
Charge Corona Wire Cleaner Error 2
SC306 D
The cleaning pad of the charge
corona wire cleaner mechanism
failed to return to its home
position.
Connectors between motor and IOB
loose, broken, defective
Charge wire dirty, defective, broken
Wire cleaning pad defective
Motor or motor board in motor unit
defective
Pre-Charge Output Error 1: Leak
SC312 C
An abnormal signal (H) was
detected continuously for 60 ms.
During this time the pre-charge
unit voltage remained less than
–3 kV for more than 50 ms.
Pre-charge unit set incorrectly.
Pre-charge unit contact is broken or
defective.
Pre-Charge Output Error 1: Grid Output
SC313 C
An abnormal signal (H) was
detected continuously for 60 ms.
During this time the pre-charge
grid voltage remained less than
–400V for more than 50 ms.
Pre-charge unit set incorrectly
Pre-charge unit contact is broken or
defective
Development Bias Error
SC320 B
An abnormal detection signal (H)
was detected continuously for 60
ms. During this time the voltage
exceeded –90µA for more than
50 ms.
Development power pack connectors
loose, broken, defective
Development unit connectors loose,
broken, defective
Development power pack defective