DEVELOPMENT AND TONER SUPPLY
3-74
3.8.5 DEVELOPMENT ENTRANCE, FRONT, REAR SIDE SEALS
1. Remove the developer and save it.
2. Replace the developer entrance seal
[A] ( x 2, hooks x 2).
3. Replace the front side seals [B].
4. Replace the rear side seals [C].
Reassembly
• When re-assembling the development unit, make sure the edges of the new side
seals align with the edges.
B234R517.WMF
B234R517A.WMF
B234R910.BMP
B234R911.BMP
[A]
Rear
Front
[B]
[C]