1016 Fine Adjust Reg Roller Speed
This SP adjusts the speed of the registration roller. The speed can be adjusted
independently for paper feed 1) when the paper is fed for 1st side printing and 2) when
paper is fed for 2nd side printing after the 1st side has been printed.
001 Font Side
002 Back Side
-3 to +3/0/0.1 mm
1105 Fusing Temperature Adjustment
001 Standby (Normal Temp Mode)
Sets standby temperature for normal temperature mode.
[140~190/*/1 deg C]
* B234/D101: 153
* B235/D102: 165
* B236/D103: 178
002 Standby (Low Temp Mode)
Sets standby temperature for low temperature mode.
[140~190/*/1 deg C]
* B234/D101: 163
* B235/D102: 175
* B236/D103: 188
003 Standby (High Temp Mode)
Sets standby temperature for high temperature mode.
[140~190/*/1 deg C]
* B234/D101: 148
* B235/D102: 160
* B236/D103: 173
004 Low Limit (Normal Temp Mode)
Sets the low limit for the fusing temperature in normal temperature mode. If the fusing
temperature falls below this temperature while operating in the normal temperature
mode, the machine will stop. After the fusing temperature rises above this
temperature, the machine resumes operation in normal temperature mode.
[120~180/*/1 deg C]
* B234/D101: 133
* B235/D102: 145
* B236/D103: 158
005 Low Limit (Low Temp Mode)
Sets the low limit for the fusing temperature in low temperature mode. If the fusing
temperature falls below this temperature while operating in the low temperature
mode, the machine will stop. After the fusing temperature rises above this
temperature, the machine resumes operation in low temperature mode.
[120~180/*/1 deg C]
* B234/D101: 143
* B235/D102: 155
* B236/D103: 168