DRUM UNIT
B234/B235/B236/D101/D102/D103 6-68 SM
allowed to operate with only the (main) charge unit operating. This will not seriously
hinder operation of the machine. However, if SP3901 (Auto Process Control
Setting) is switched on, auto process control will execute to adjust the new
conditions around drum because the pre-charge unit is not operating.
NOTE:
• When auto process control is executed under these conditions, the ID sensor
adjustment is not done.
• After you repair the pre-charge unit, to recover from SC312 or SC313, you must
change the setting of SP2002 001 from "0" (Off) to "1" (On).
Off
On
SC312/SC313
Machine Stops
Switch Power Off/On
SP3901
(Auto Process Control
Setting)
The machine excutes Auto
Process Control
End
SP2002 001 On -> Off
(Set Pre-Charge Mode)
B234D559.WMF