FUSING
B234/B235/B236/D101/D102/D103 6-152 SM
Fusing Temperature Control and Machine Status - Overview
Fusing temperature control operates differently depending on the status of the
machine:
At power on (cold/warm starts)
During standby
During machine operation (low limit, paper sizes)
Low power mode (during and immediately after)
In Energy Saver mode
Fusing control in each operation mode is described below.
NOTE:
In the descriptions below, the "1", "2", "3" notations refer to the fusing lamp
number (6.16.4 - Overview).
Fusing Temperature Control at Power On (Cold/Warm Starts)
1. After the machine power is turned off/on
If the fusing unit temperature is below the temperature set with SP1105 010,
three fusing lamps switch on in this order: 3 Æ 2 Æ 1.
-or-
If the fusing temperature is above the temperature set with SP1105 010, two
lamps (2 and 3) switch on in this order: 3 Æ 2
Default Values
B234/
D101
B235/
D102
B236/
D103
SP No.
Fusing Lamp Switching
for warm-up
99°C 99°C 95°C
SP1105 010
20 to 190°C
2. When the temperature rises to the temperature set with SP1105 010, fusing
lamp 1 switches off.
3. When the temperature reaches the standby temperature, fusing lamps 3 and 2
switch off in this order: 3 Æ 2