6. Level the fan fold unit.
The fan fold unit must be level within ±0.15 mm/m on the right, left, and rear sides.
Set the level on each side of the fan fold unit as shown above.
Level the sides of the fan fold unit in this order: À right, Á rear, Â left.
Use a wrench to adjust the nuts on the right leg [1] and left leg [2] to raise or lower the fan fold
unit until it is level.
Bridge Unit BU6500 (D407) Folder FD6500A (B889)