Checking the Fan Fold Unit Circuit Breaker
On the fan fold unit, check that the main switch [1] and heater switch [2] are off.
1. Connect the fan fold unit power cord to the power source.
2. Look at the circuit breaker [3].
With the horizontal line displayed on the circuit breaker, use the tip of a small screwdriver to
depress the breaker test button.
The circuit breaker should flip to the "O" position. This indicates that the circuit breaker is operating
normally.
If the circuit breaker does not flip to the "O" position, the circuit breaker must be replaced.
Push the lever to display the vertical line again and reset the machine for normal operation.
The fan fold unit will not switch on if the lever remains at the "O" position.
3. Disconnect the fan fold unit power cord from the power source.
4. Reattach all covers and doors.