1. Set the pressure lever [1] to the left.
2. Plug in the power cable and switch the main power switch on.
3. Press .
4. Enter "107".
5. Hold down for more than 3 seconds.
6. On the touch panel, touch "Copy SP".
7. Enter 2923, press [#] , then push [Start] to execute Drum Set Mode.
8. After it has finished, set the pressure lever [1] to the right.
9. If you have replaced the OPC drum, enter 3001 002, press [#], then press Start to initialize the
ID sensor.