25 Blank Image
2916 Fine Magnification
This SP supplements the rate of magnification and paper selected by the user for the job in
order to maintain the fine magnification for the paper in use.
SP2916 Settings Table
Type Mode Direction [Range/Default/Step]
1
Plain
1 to 4
Main Scan [-1 to 1/0/0.01%]
2 Sub Scan [-0.8 to 1/0/0.1%]
3
Trans
Main Scan [-1 to 1/0/0.01%]
4 Sub Scan [-0.8 to 1/0/0.1%]
5
Film
Main Scan [-1 to 1/0/0.01%]
6 Sub Scan [-0.8 to 1/0/0.1%]
7
Recycled
Main Scan [-1 to 1/0/0.01%]
8 Sub Scan [-0.8 to 1/0/0.1%]
9
Plain
5
Main Scan [-1 to 1/0/0.01%]
10 Sub Scan [-0.8 to 1/0/0.1%]
11
Trans
Main Scan [-1 to 1/0/0.01%]
12 Sub Scan [-0.8 to 1/0/0.1%]
13
Film
Main Scan [-1 to 1/0/0.01%]
14 Sub Scan [-0.8 to 1/0/0.1%]
15
Recycled
Main Scan [-1 to 1/0/0.01%]
16 Sub Scan [-0.8 to 1/0/0.1%]
2923
Execute Cleaning Blade Replace Mode
Do this SP after replacing the drum or cleaning blade
System Service Mode
127