The "S1 Direction" in the two SP codes below refers to the Fold length Sensor (L) (S1) shown in the illustration
above.
21
Reverse Timing: Last Fold: S1 Direction
When the last fold is opposite the direction of output, after the trailing edge of the paper passes
the cross folder entrance sensor and feeds 94.6 mm toward Fold Length Sensor (S1), the cross
fold motor and transport motor go off. This 94.6 mm distance that the paper feeds can be
adjusted in the range ±50 mm. Raising or lowering the setting increases or decreases the time
before the motors stop.
[-50 to +10/-9/1 mm]
22
Fold Plate Timing: Last Fold: S1 Direction
When the last fold is a valley fold, the cross fold motor turns on, feeds the paper toward the
paper exit, and then raises fold plate 1 (upper fold plate) once the paper has fed 2 mm toward
Fold Length Sensor (S1). This 2 mm distance that the paper feeds can be adjusted in the range
0 to +30 mm. Raising the setting increases the distance the paper feeds.
[0 to 30/4/1 mm]
31
Fold Motor Power: Paper Entrance
This SP sets the amount of voltage fed to the cross fold motor until the first fold is done in the
cross folder unit.
[0 to 3/0/1]
8. Appendix: SP Mode Tables