System SP Tables-2
D017/D018/D019/D020/D084/D085 4-18 SM Appendix
2803* Developer Initialization Data
1
Vts
When the machine detects a new PCU (photoconductor unit) in the
machine, it checks the heat seals at the creation of the first ID sensor
pattern. After the agitator is rotated for 30 sec., the machine creates the
second ID sensor pattern and corrects the reference value of the TD sensor.
The corrected reference value for the TD sensor is recorded here.
2
ID Sensor PWM Value
Displays the PWM value of the ID sensor after performing the developer
initialization.
2804
New PCU Check DFU
This SP determines whether the machine is set to recognize a new PCU.
[0 to 1/0/1]
0: New PCU recognition on.
1: New PCU recognition off.