System Service Mode
SM Appendix 9-211 D037/D038/D040/D041
Appendix:
SP Mode
Tables
0: Uses the RCG certification
1: Does no use the RCG certification
RCG Connect Timeout
008
Specifies the connect timeout interval when calling the RCG.
[1 to 90 / 10 / 1 second /step]
RCG Write Timeout
009
Specifies the write timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
RCG Read Timeout
010
Specifies the read timeout interval when calling the RCG.
[1 to 100 / 60 / 1 second /step]
Port 80 Enable
011
Enables/disables access via port 80 to the SOAP method.
[0 or 1 / 0 / – ]
0: Disabled
1: Enabled
012 @Remote Communication Permission Setting
013 RFU Timing
RCG – C Registed
021
This SP displays the Cumin installation end flag.
0: Installation not completed
1: Installation completed
RCG – C Registed Detail
022
This SP displays the Cumin installation status.
0: Basil not registered
1: Basil registered
2: Device registered
023 Connect Type (N/M)

Table of Contents