No.
Definition
Symptom Possible Cause
460 B
Isolation voltage error
Detecting "0" (Abnormal) ten times in
series (200ms) while monitoring "HVP:
D: Output error detection signal" every
20m seconds.
(Reboot the machine to clear this SC)
490 B
Toner bottle motor overcurrent
Detecting "Low" for more than 200msec
while the motor on.
Motor locked up due to overcurrent to
the drive section.
Defective the motor drive.
500 B
Main motor error
Detecting “High” condition twenty times
in series during watching each lock
signal after switching motor on.
Overload
Defective main motor drive
541 A
Fusing thermistor disconnection
Detecting the temperature remains lower
than 0 degrees Celsius for 5 seconds.
Thermistor disconnection
Defective connector part
542 Fusing reload failed
-001 A
Fusing temperature warm-up error
The fusing temperature doesn’t rise
by more than 7 degrees for two
seconds; and this happens 5 times
consecutively.
The measure is start in 3.5 seconds after
activation of the heater.
This monitoring will stop in the case of
reaching the reload temperature.
Defective thermistor
Power source is out of warranty