B
[00FF]: Detailed error code
Cache access error in the CPU
• Defective CPU
•
Defective local bus
1. Turn the main power switch off and
on.
2. Reinstall the system program.
3. Replace the controller board.
B
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does not
operate even though it is executed
on purpose.
• Defective CPU devices
1.
Replace the controller board.
B
[060A-060E]: Detailed error code
Cut-in command does not operate
when it is executed.
• Defective CPU devices
•
Defective ASIC devices
1. Replace the controller board.
B
[0610]: Detailed error code
Timer cut-in does not operate even
though it is set.
• Defective CPU devices
1.
Replace the controller board.
B
[0612]: Detailed error code
Cut-in in ASIC occurs.
• Defective ASIC
•
Defective devices in which ASIC
detects cut-in.
1. Replace the controller board.
B
[06FF]: Detailed error code
The pipeline clock frequency rate is
different from the prescribed value.
• Defective CPU devices
•
Mode bit data error, which is used for
initializing CPU.
1. Replace the controller board.
6. Troubleshooting