EasyManua.ls Logo

Ricoh D127 - Page 177

Ricoh D127
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B
[0702]: Detailed error code
The result when the program is
executed in the command cache is
different from desirable value.
Insufficient CPU cache
Insufficient memory process speed
1. Replace the controller board.
2. Replace the RAM DIMM.
B
[0709, 070A]: Detailed error code
Even you write the data in the only
cache of memory, the data is
actually written in another area (not
cache) of memory.
Defective CPU devices
Incorrect SPD
Boot mode setting error
1. Replace the controller board.
2. Replace the RAM DIMM.
B
[0801, 0804, 0807, 0808, 0809, 80A]: Detailed error code
An error occurs when checking the
TLB.
Defective CPU devices
1.
Replace the controller board.
B
[4002-4005]: Detailed error code
The calculation error in the CPU
occurs.
Defective CPU
1.
Replace the CPU.
821 Self-Diagnostic Error: ASIC
[0B00] B
ASIC error
The write-&-verify check error has
occurred in the ASIC.
Defective controller board
1.
Replace the controller.
[0B06] B
ASIC not detected
The ASIC of the I/O is not detected.
ASIC (controller board defective)
Poor connection between North
Bridge and PCI I/F.
1. Replace controller board.
SC Tables
175

Table of Contents

Other manuals for Ricoh D127

Related product manuals