[0D05] B
Timer error between ASIC and CPU
The CPU checks if the ASIC timer
works properly compared with the
CPU timer. If the ASIC timer does not
function in the specified range, this
SC code is displayed.
System firmware problem
Defective RAM-DIMM
Defective controller
Reinstall the controller system
firmware.
1. Replace the RAM-DIMM.
2. Replace the controller board.
[50A1] B
Video bridge device (ASIC) error 1
The CPU does not detect the video
bridge device.
Defective I/F between the video
bridge device and controller
1.
Replace the controller board.
[50A2] B
Video bridge device (ASIC) register error 1
The CPU detects the video bridge
device, but detects error data from
the video bridge device.
Defective I/F between the video
bridge device and controller
1.
Replace the controller board.
822
Self-diagnostic error: HDD (Hard Disk Drive)
[XXXX]: Detailed error code
When the main switch is turned on or starting the self-diagnostic, the HDD stays busy for
the specified time or more.
[3003] C Timeout error Loose connection
Defective HDD
Defective controller
1. Check that the HDD is correctly
connected to the controller.
2. Replace the HDD or the controller
[3004] C Command error
823 Self-diagnostic Error: NIB
[6101] C
MAC address check sum error
The result of the MAC address check
sum does not match the check sum
stored in ROM.
Defective controller
1.
Replace the controller.