[110C] C
Loopback connector is connected but
check results in an error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector
defective
1. Replace the controller board.
[1120] C
Centronic loopback connector is not
connected for detailed self-diagnostic
test.
Centronic loopback connector not
connected correctly
Centronic loopback connector
defective
ASIC device defective
1. Replace the controller board.
838
[2701]
B
Self-diagnostic Error: Clock Generator
A verify error occurred when setting
data was read from the clock
generator via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
1. Replace the controller board.
839 USB NAND Flash ROM error
839
B
Serial Flash access error
[9001]
The result of reading and writing in
software status register of Serial
Flash, the device for certification,
came to an error.
Defective Serial Flash
[9101] B
The ID of the USB NAND Flash ROM
cannot be read.
Defective controller board
1.
Replace the controller board.
[9110] B
The USB NAND Flash ROM is
disconnected.
840 B
EEPROM access error
While I/O operation to EEPROM
Three times retry is ineffective after
reading error
Writing error occurs.
Defective EEPROM
SC Tables