857 C
USB I/F Error
USB interface error is detected.
• Defective controller
1.
Check the USB connections, and
make sure that they are securely
connected.
2. Replace the controller board.
858
HDD Encryption unit error 1
A serious error occurs when data is encrypted to update an encryption key with the HDD
encryption unit.
[0]
A
Encryption key acquisition error:
The controller fails to get a new
encryption key.
• Defective controller board
1.
Replace the controller board.
[1]
Encryption key setting for HDD error:
The controller fails to copy a new
encryption key to the HDD.
• Defective SATA chip on the
controller board
1.
Replace the controller board.
[2]
NVRAM data encryption error 1:
An error occurs while the NVRAM
data is encrypted.
• Defective NVRAM on the controller
board
1. Replace the NVRAM.
[30]
NVRAM data encryption error 2:
An error occurs before the NVRAM
data is encrypted.
• Defective controller board
1.
Replace the controller board.
[31]
Other error:
A serious error occurs while the data
is encrypted.
• Same as SC991
859
HDD Encryption unit error 2
A serious error occurs when the HDD data is encrypted to update an encryption key with
the HDD encryption unit.
SC Tables
181