2915* Polygon Motor Idling Time
2915 1 Idling Time ADJ [0 to 60 / 10 / 1 sec/step]]
Adjusts
before or after printing polygon motor
idling time.
2915 2 Post Idling Time ADJ
2921* Toner Supply Mode
2921 1
[0: Normal 1 / 1: Normal 2 / 2: Fixed 1 / 3: Fixed 2]
Selects the toner supply mode. Keep the default setting as long as the TD sensor is
working normally. (Default= 0)
2922* Toner Supply Time [0.1 to 5.0 / 0.5 / 0.1 sec/step]
2922 1
Adjusts the toner supply time. The toner supply motor remains on for the specified time.
Specify a greater value if the user tends to make many copies having high proportions of
solid black image areas.
2923* Toner Recovery Time [1 to 60 / 30 / 1 sec/step]
2923 1
Adjusts the toner supply time under the condition of “Toner End” or “Toner Near End”
detected.
2925* Toner Supply Ratio [0 to 7 / 0 / 1 /step]
2925 1
The ratio adjustment SP available only when “SP2-921-1” setting is “2 (Fixed1)”. Each
value represents as follows:
0: x1
1: x2
2: x4
3: x8
4: x12
5: x16
6: Continuously supply
7: No supply
2926* Standard Vt [0.00 to 5.00 / 2.4 / 0.05 V/step] DFU
System Service Mode