Code Meaning Suggested Cause/Action
6-05
G3 ECM - facsimile data
frame not received within 18 s
of CFR, but there was no line
fail
Check the line connection.
Check for a bad line or defective remote terminal.
Replace the FCU.
Try adjusting the rx cable equalizer
Cross reference
Rx cable equalizer - G3 Switch 07 (PSTN)
6-06
G3 ECM - coding/decoding
error
Defective FCU.
The other terminal may be defective.
6-08
G3 ECM - PIP/PIN received in
reply to PPS.NULL
The other end pressed Stop during communication.
The other terminal may be defective.
6-09 G3 ECM - ERR received
Check for a noisy line.
Adjust the tx levels of the communicating machines.
See code 6-05.
6-10
G3 ECM - error frames still
received at the other end after
all communication attempts at
2400 bps
Check for line noise.
Adjust the tx level (use NCU parameter 01 or the
dedicated tx parameter for that address).
Check the line connection.
Defective remote terminal.
6-21
V.21 flag detected during high
speed modem communication
The other terminal may be defective or incompatible.
6-22
The machine resets the
sequence because of an
abnormal handshake in the V.
34 control channel
Check for line noise.
If the same error occurs frequently, replace the FCU.
Defective remote terminal.
6-99
V.21 signal not stopped within
6 s
Replace the FCU.
13-17
SIP user name registration
error
Double registration of the SIP user name.
Capacity for user-name registration in the SIP server
is not sufficient.