EasyManua.ls Logo

Ricoh D127 - Page 464

Ricoh D127
474 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Address Function Unit Remarks
6805AB CNG on time 20 ms Factory setting: 500 ms
6805AC CNG off time 20 ms Factory setting: 3000 ms
6805AD
Number of CNG cycles required for
detection
-
The data is coded in the
same way as address
680533.
6805AE Not used - Do not change the settings.
6805AF
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (high byte)
Hz (BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B0
Acceptable AI short protocol tone
(800Hz) detection frequency upper
limit (low byte)
6805B1
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (high byte)
Hz(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
6805B2
Acceptable AI short protocol tone
(800Hz) detection frequency lower
limit (low byte)
6805B3
Detection time for 800 Hz AI short
protocol tone
20 ms Factory setting: 360 ms
6805B4 PSTN: Tx level from the modem -N – 3 dBm
SP2-103-002 (parameter
01).
6805B5 PSTN: 1100 Hz tone transmission level
- N 6805B4 - 0.5N 6805B5 –3.5 (dB)
See Note 7.
6805B6 PSTN: 2100 Hz tone transmission level
- N6805B4 - 0.5N 6805B6 –3 (dB)
See Note 7.
6805B7 PABX: Tx level from the modem - dBm
6805B8 PABX: 1100 Hz tone transmission level - N 6805B7 - 0.5N 6805B8 (dB)
6805B9 PABX: 2100 Hz tone transmission level - N 6805B7 - 0.5N 6805B9 (dB)
5. Appendix: Fax Service Program