Bit Switches
D127/D128 5-56 SM Appendix
3 Not used Do not change the settings
4
Maximum allowable frame
interval during image data
reception.
0: 5 sec 1: 13 sec
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5 Not used Do not change the settings.
6
Reconstruction time for the first
line in receive mode
0: 6 sec 1: 12 sec
When the sending terminal is controlled by a
computer, there may be a delay in receiving
page data after the local machine accepts
set-up data and sends CFR. This is outside the
T.30 recommendation. But, if this delay occurs,
set this bit to 1 to give the sending machine
more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
7 Not used Do not change the settings.
G3 Switch 0B Not used (do not change the settings).