NCU Parameters
D629 152 SM
Address Function Unit Remarks
6805BE to
6805C6
Not used
-
Do not change the
settings.
6805C7
Bits 0 to 3 Not used
Bit 4 = V.34 protocol dump 0: Simple, 1: Detailed (default)
Bits 5 to 7 Not used.
6805C8 to
6805D9
Not used
-
Do not change the
settings.
6805DA T.30 T1 timer 1 s
6805E0 bit
3
Maximum wait time for post
message
0: 12 s
1: 30 s
1: Maximum wait time
for post message
(EOP/EOM/MPS) can
be changed to 30 s.
Change this bit to “1” if
communication errors
occur frequently during
V.17 reception.
6805E3
Bits 0 and 1 DCV (TIP/RING) Voltage
Bit 1:0, Bit 0: 0 = 3.1 V
Bit 1:0, Bit 0: 1 = 3.2 V
Bit 1:1, Bit 0: 0 = 3.35 V
Bit 1:1, Bit 0: 1 = 3.5 V
Bits 2 and 3 MINI (minimum loop electric current)
Bit 2:0, Bit 3: 0 = 10 mA
Bit 2:0, Bit 2: 1 = 12 mA
Bit 2:1, Bit 3: 0 = 14 mA
Bit 2:1, Bit 3: 1 = 16 mA
Bits 6 and 7 ACIM (AC impedance)
Bit 7:0, Bit 6: 0 Bit 5:0, Bit 4: 0= 600
Bit 7:0, Bit 6: 0 Bit 5:1, Bit 4: 0= TBR21