Fold Adjustments
SM 77 D454/D615
Multi-Folding
Unit
D454/D615
FM3 Letter Fold-out
User Tool Adjustment (Operator, Skilled Operator)
The following standard adjustment of "S1" can be done by the operator or skilled operator in
the User Tools mode. Only "S1" can be adjusted by the operator, as shown in the table
below.
Size Setting Default Range Setting Default Range
A3 SEF S1 0 mm ±10 mm --- --- ---
B4 SEF S1 0 mm ±10 mm --- --- ---
A4 SEF S1 0 mm ±10 mm --- --- ---
DLT S1 0 mm ±10 mm --- --- ---
LG S1 0 mm ±10 mm --- --- ---
LT SEF S1 0 mm ±10 mm --- --- ---
Other S1 0 mm ±10 mm --- --- ---
Pitch Adj. 1 mm
Engine SP Adjustment
The following fine adjustment of "S2" and "L" can be done by the customer engineer in the
SP mode.