SC500: Feed, Transport, Duplex, and Fusing
SM Appendix 2-29 D131/D132/D133
Service Call
Conditions
SC515-00 C
Duplex jogger motor error 1
When the jogger fence moves to the home position, the jogger HP
sensor does not turn on even if the jogger fence motor has moved
the jogger fence 153.5 mm.
Paper or other obstacle has jammed mechanism
Sensor connector disconnected or defective
Sensor defective
SC516-00 C
Duplex jogger motor error 2
When the jogger fence moves from the home position, the jogger
fence HP sensor does not turn off even if the jogger motor has
moved the jogger fence 153.5 mm.
Paper or other obstacle has jammed mechanism
Sensor connector disconnected or defective
Sensor defective
SC530-00 D
Main fan error
The main fan motor lock signal goes high for 5 s while the fan is on.
Fan motor overloaded due to obstruction
Fan connector disconnected
SC540-01 D
Fusing exit motor error
The PLL lock signal was low for 2 s during motor operation.
Motor lock caused by physical overload
Motor drive PCB defective