1107 Start Fusing Temp. Time Ad.
This SP allows you to set when to start the fusing temperature adjustment for
the center and end heating lamps.
1 Center Lamp Temperature
D131/D132: [150 to 205/205/1 deg C]
D133: [150 to 190/190/1 deg C]
2 End Lamp Temperature
D131/D132: [150 to 205/205/1 deg C]
D133: [150 to 190/190/1 deg C]
3 Center Lamp Actual Time
D131/D132: [0 to 120/60/1 sec.]
D133: [0 to 60/10/1 sec.]
4 End Lamp Actual Time
D131/D132: [0 to 120/55/1 sec]
For Only TWN [0 to 120/60/1 sec]
D133: [0 to 60/10/1 sec]
5 Center Lamp Temp (Small Size Paper)
D131/D132: [180 to 205/205/1 deg C]
D133: [175 to 190/190/1 deg C]
6 End Lamp Actual Time (Small Size Paper)
D131/D132: [0 to 120/60/1 sec.]
D133: [0 to 60/10/1 sec]
7 Center Lamp Temp (Thick Paper)
D131/D132: [180 to 205/205/1 deg C]
D133: [175 to 200/200/1 deg C]
8 End Lamp Actual Time (Thick Paper)
D131: [0 to 120/0/1 sec.]
D132: [0 to 120/5/1 sec.]
D133: [0 to 120/10/1 sec.]