SP5000 Mode: SP5024 to SP5816
D131/D132/D133 3-102 SM Appendix
5416 Access Information
1 Access Use Max Num
Limits the number of users used by the access exclusion and password attack
detection functions.
[50 to 200 / 200 / 1 users/step]
2 Access Password Max Num
Limits the number of passwords used by the access exclusion and password
attack detection functions.
[50 to 200 / 200 / 1 password/step]
3 Monitor Interval
Sets the processing time interval for referencing user ID and password
information.
[1 to 10 / 3 / 1 sec./step]
5417 Access Attack
1 Access Permissible Number
Sets a limit on access attempts when an excessive number of attempts are
detected for MFP features.
[0 to 500 / 100 / 1/step]
2 Attack Detect Time
Sets the length of time when the frequency of access to MFP features are
monitored.
[10 to 30 / 10 / 1 sec./step]
3 Productivity Fall Wait
Sets the wait time to slow down the speed of certification when an excessive
number of access attempts have been detected.
[0 to 9 / 3 / 1 sec./step]