Main SP Tables-2-1
System Maintenance Section 2-159 D146/D147/D148/D149/D150
013
Coefficient a: M *ENG [0.00 to 1.00 / 0.06 / 0.01/step]
Coefficient a, M for calculating Electrify roller fatigue.
014
Coefficient a: Y *ENG [0.00 to 1.00 / 0.06 / 0.01/step]
Coefficient a, Y for calculating Electrify roller fatigue.
015
Coefficient b: K *ENG [0.00 to 9.00 / 0.50 / 0.01/step]
Coefficient b, K for calculating Electrify roller fatigue.
016
Coefficient b: C *ENG [0.00 to 9.00 / 0.50 / 0.01/step]
Coefficient b, C for calculating Electrify roller fatigue.
017
Coefficient b: M *ENG [0.00 to 9.00 / 0.50 / 0.01/step]
Coefficient b, M for calculating Electrify roller fatigue.
018
Coefficient b: Y *ENG [0.00 to 9.00 / 0.50 / 0.01/step]
Coefficient b, Y for calculating Electrify roller fatigue.
2021 [Background Pot Correction]
001
Display:K *ENG [0 to 90 / 0 / 1V/step]
DC bias correction value, K
002
Display:C *ENG [0 to 90 / 0 / 1V/step]
DC bias correction value, C
003
Display:M *ENG [0 to 90 / 0 / 1V/step]
DC bias correction value, M
004
Display:Y *ENG [0 to 90 / 0 / 1V/step]
DC bias correction value, Y
005
Setting1:K *ENG [0 to 90 / 10 / 10V/step]
Electric potential correction amount 1 against Electrify roller fatigue amount, K
006
Setting1:C *ENG [0 to 90 / 10 / 10V/step]
Electric potential correction amount 1 against Electrify roller fatigue amount, C