Main SP Tables-2-1
D146/D147/D148/D149/D150 2-164 System Maintenance Section
Calculation value K, for calculating temporary value when RTC can not be
acquired.
006
PCU Rotation Time After
Correction: C
*ENG [0 to 9999999 / 0 / 1/step]
Calculation value C, for calculating temporary value when RTC can not be
acquired.
007
PCU Rotation Time After
Correction: M
*ENG [0 to 9999999 / 0 / 1/step]
Calculation value M, for calculating temporary value when RTC can not be
acquired.
008
PCU Rotation Time After
Correction: Y
*ENG [0 to 9999999 / 0 / 1/step]
Calculation value Y, for calculating temporary value when RTC can not be
acquired.
009
Threshold1:K *ENG [0 to 4000 / 30 / 1/step]
Threshold 1 K, against Electrify roller fatigue amount.
010
Threshold1:C *ENG [0 to 4000 / 30 / 1/step]
Threshold 1 C, against Electrify roller fatigue amount.
011
Threshold1:M *ENG [0 to 4000 / 30 / 1/step]
Threshold 1 M, against Electrify roller fatigue amount.
012
Threshold1:Y *ENG [0 to 4000 / 30 / 1/step]
Threshold 1 Y, against Electrify roller fatigue amount.
013
Threshold2:K *ENG [0 to 4000 / 70 / 1/step]
Threshold 2 K, against Electrify roller fatigue amount.
014
Threshold2:C *ENG [0 to 4000 / 70 / 1/step]
Threshold 2 C, against Electrify roller fatigue amount.
015
Threshold2:M *ENG [0 to 4000 / 70 / 1/step]
Threshold 2 M, against Electrify roller fatigue amount.