Main SP Tables-3
D146/D147/D148/D149/D150 2-362 System Maintenance Section
002 C *ENG
003 M *ENG
004 Y *ENG
3131 [Vt TE Thresh]
001
Delta Vt Thresh *ENG [0.00 to 5.00 / 0.50 / 0.01V/step]
Threshold to start adding delta Vt after NE.
002
Delta Vt Sum Thresh *ENG [0 to 99 / 10 / 1V/step]
Threshold to decide TE after NE.
011
Delta Vt Thresh BF NE *ENG [0.00 to 5.00 / 0.50 / 0.01V/step]
Threshold to start adding delta Vt before NE.
012
Delta Vt Sum Thresh BF NE *ENG [0 to 99 / 10 / 1V/step]
Threshold to decide TE before NE.
3132
[Delta Vt Sum]
Added value of delta Vt.
001 Bk *ENG
[0.00 to 99.00 / 0.00 / 0.01V/step]
002 C *ENG
003 M *ENG
004 Y *ENG
3133 [TE Detect :Set]
001
Set Sheets(Min) *ENG [0 to 50 / 10 / 1sheet/step]
Sets min. assured sheets to display toner end after toner near end is fixed.
002
Set Sheets(Max) *ENG [0 to 5000 / 1000 / 1sheet/step]
Sets max. assured sheets to display toner end after toner near end is fixed.