SC
[Level]
Symptom Possible Cause/Required Action
365
[D]
TD sensor Output minimum error [M]
Same as SC 364
366
[D]
TD sensor: Output minimum error [C]
Same as SC 364
367
[D]
TD sensor: Output minimum error [Y]
Same as SC 364
368
[D]
TD sensor: Initial control voltage error [K]
Vt is less than 1 V even
though the control power
voltage is adjusted to the
maximum.
Vt is more than 1 V even
though the control power
voltage is adjusted to the
minimum.
Defective connector connection
Defective TD sensor
The toner density in the developer is different from
the initial condition.
1. Replace the PCU.
369
[D]
TD sensor: Initial control voltage error [M]
Same as SC 368
370
[D]
TD sensor: Initial control voltage error [C]
Same as SC 368
371
[D]
TD sensor: Initial control voltage error [Y]
Same as SC 368
372
[D]
TD sensor: Initial adjustment error [K]
Vt is not (A ±0.2) when initial
setting for TD sensor is
executed.
A = SP3011-001 for [K]
Defective connector connection
Defective TD sensor
The toner density in the developer is different from
the initial condition.
1. Replace the PCU.