SC
[Level]
Symptom Possible Cause/Required Action
[B]
[00FF]: Detailed error code
Cache access error in the CPU
Defective CPU
Defective local bus
1. Turn the main power switch off and on.
2. Reinstall the system program.
3. Replace the controller board.
[B]
[0601, 0602, 0605, 0606, 0607, 0609]: Detailed error code
Exceptional command does
not operate even though it is
executed on purpose.
Defective CPU devices
1. Replace the controller board.
[B] [060A-060E]: Detailed error code
Cut-in command does not
operate when it is executed.
Defective CPU devices
Defective ASIC devices
1. Replace the controller board.
[B]
[0610]: Detailed error code
Timer cut-in does not operate
even though it is set.
Defective CPU devices
1. Replace the controller board.
[B]
[0612]: Detailed error code
Cut-in in ASIC occurs.
Defective ASIC
Defective devices in which ASIC detects cut-in.
1. Replace the controller board.
[B]
[06FF]: Detailed error code
The pipeline clock frequency
rate is different from the
prescribed value.
Defective CPU devices
Mode bit data error, which is used for initializing
CPU.
1. Replace the controller board.
[B]
[0702]: Detailed error code