Loading...
SC
[Level]
Symptom Possible Cause/Required Action
[6105]
[B]
PHY IC loop-back error
An error occurred during the
loop-back test for the PHY IC
on the controller.
Same as SC823-[6101]
824
[B]
Self-diagnostic Error: NVRAM
The controller cannot
recognize the standard
NVRAM installed or detects
that the NVRAM is defective.
NVRAM damaged or abnormal
Backup battery has discharged
NVRAM socket damaged
1. Replace the NVRAM.
826 Self-diagnostic Error: RTC/Optional NVRAM
[1501]
[B]
Clock error
An RTC device is
recognized, and the
difference between the
RTC device and the CPU
exceeds the defined limit.
No RTC device is
recognized.
RTC defective
NVRAM without RTC installed
Backup battery discharged
1. Replace the NVRAM with another NVRAM with an
RTC device.
[15FF]
[B]
RTC not detected
The RTC device is not detected.
NVRAM without RTC installed
Backup battery discharged
1. Replace the NVRAM with another NVRAM with an
RTC device.
827 Self-diagnostic Error: RAM
[0201]
[B]
Verification error
Error is detected during a
write/verify check for the
standard RAM (SDRAM
DIMM).
Loose connection
Defective SDRAM DIMM
Defective controller
1. Replace the SDRAM DIMM.
Service Call Conditions