Adjusts the threshold temperature for the added idling rotation.
1104 031
1st Pot Add Time *EGB [0 to 10 / 2 / 0.1 sec/step]
Adjusts the added idling rotation time. This SP is activated when the fusing temperature
does not reach the specified temperature with SP1104-30.
1105
[Fusing Temp.] Fusing Temperature
(Paper Type, Mode, Color, Process Speed)
Paper Type -> N: Plain paper 1, N2: Plain paper 2, TC: Thick, TN: Thin, SP: Special,
OHP, ENV: Envelope, GL: Glossy paper, TK2: Thick paper 2
Mode -> Simple [one-sided] or Duplex
Color -> K: Black only, FC: Full color
Process Speed -> LS: Low speed, RS: Regular speed
Reload: Print ready, between jobs
Adjusts the fusing unit temperature for each mode.
1105 022 Reload Temp. *EGB [100 to 180 / 160 / 1deg /step]
1105 025 TC1: Simple: [K] *EGB
[120 to 180 / 160 / 1deg /step]
1105 026 TC1: Duplex: [K] *EGB
1105 027 TC1: Simple: [FC] *EGB
1105 028 TC1: Duplex: [FC] *EGB
1105 029 TC2: Simple: [K] *EGB
1105 031 TC2: Simple: [FC] *EGB
1105 033 N: Simple: [K]: LS *EGB [120 to 180 / 145 / 1deg /step]
1105 034 N: Simple: [K]: RS *EGB [120 to 180 / 160 / 1deg /step]
1105 035 N: Duplex: [K]: LS *EGB [120 to 180 / 145 / 1deg /step]
1105 036 N: Duplex: [K]: RS *EGB [120 to 180 / 160 / 1 deg /step]
1105 037 N: Simple: [FC]: LS *EGB [120 to 180 / 145 / 1deg /step]
1105 039 N: Simple: [FC]: RS *EGB [120 to 180 / 160 / 1deg /step]
1105 040 N: Duplex: [FC]: LS *EGB [120 to 180 / 145 / 1deg /step]
Service Mode Table