1105 042 N: Duplex: [FC]: RS *EGB [120 to 180 / 160 / 1deg /step]
1105 043
Check Temp. Time *EGB [0 to 10 / 2.0 / 0.1 sec/step]
Adjusts the rotation time before checking the fusing unit temperature. If the main switch is
turned on and off for a short time, it might be possible that the checked temperature is
high even though the whole of the fusing unit is not high enough for printing condition.
1105 049 N2: Simple: [K]: LS *EGB [120 to 180 / 150 / 1deg /step]
1105 050 N2: Simple: [K]: RS *EGB [120 to 180 / 165 / 1deg /step]
1105 051 N2: Duplex: [K]: LS *EGB [120 to 180 / 150 / 1deg /step]
1105 052 N2: Duplex: [K]: RS *EGB [120 to 180 / 165 / 1deg /step]
1105 053 N2: Simple: [FC] LS *EGB [120 to 180 / 150 / 1deg /step]
1105 054 N2: Simple: [FC] RS *EGB [120 to 180 / 165 / 1deg /step]
1105 055 N2: Duplex: [FC] LS *EGB [120 to 180 / 150 / 1deg /step]
1105 056 N2: Duplex: [FC] RS *EGB [120 to 180 / 165 / 1deg /step]
1105 057 TN: Simple: [K]: LS *EGB [120 to 180 / 135 / 1deg /step]
1105 058 TN: Simple: [K]: RS *EGB [120 to 180 / 150 / 1deg /step]
1105 059 TN: Duplex: [K]: LS *EGB [120 to 180 / 135 / 1deg /step]
1105 060 TN: Duplex: [K] RS *EGB [120 to 180 / 150 / 1deg /step]
1105 061 TN: Simple: [FC] LS *EGB [120 to 180 / 135 / 1deg /step]
1105 062 TN: Simple: [FC] RS *EGB [120 to 180 / 150 / 1deg /step]
1105 063 TN: Duplex: [FC] LS *EGB [120 to 180 / 135 / 1deg /step]
1105 064 TN: Duplex: [FC] RS *EGB [120 to 180 / 150 / 1deg /step]
1105 065 SP1: Simple: [K] LS *EGB [120 to 180 / 165 / 1deg /step]
1105 067 SP1: Duplex: [K] LS *EGB [120 to 180 / 165 / 1deg /step]
1105 069 SP1: Simp.: [FC] LS *EGB [120 to 180 / 165 / 1deg /step]
1105 071 SP1: Dupl.: [FC] LS *EGB [120 to 180 / 165 / 1deg /step]
1105 073 ENV: Simple: [K] RS *EGB
[120 to 180 / 170 / 1deg /step]