9906 007 Vpp1: MH *EGB [0 to 3000 / 1810 / 1 V/step]
9906 008 Vpp2: MH *EGB [0 to 3000 / 2060 / 1 V/step]
9906 009 Vpp1: HH *EGB [0 to 3000 / 1770 / 1 V/step]
9906 010 Vpp2: HH *EGB [0 to 3000 / 2020 / 1 V/step]
9908
[Background Po.] Background Potential
Adjusts the upper or lower threshold for disabling the charge bias.
9908 001 Upper Limit *EGB
[0 to 300 / 130 / 1/step]
9908 002 Lower Limit *EGB
9910 [Factory Adj.]
9910 001 Charge Output *EGB Performs the charge output.
9910 003 [All] TC Initial *EGB Performs the toner supply for all colors.
9910 004 [All] TC Initial *EGB Performs the developer initializing for all colors.
9910 005 [K] TC Initial *EGB Performs the developer initializing for black.
9910 006 [M] TC Initial *EGB Performs the developer initializing for magenta.
9910 007 [C] TC Initial *EGB Performs the developer initializing for cyan.
9910 008 [Y] TC Initial *EGB Performs the developer initializing for yellow.
9910 010 [K] Toner FillUP *EGB Fills up the black toner.
9910 011 [M] Toner FillUP *EGB Fills up the magenta toner.
9910 012 [C] Toner FillUP *EGB Fills up the cyan toner.
9910 013 [Y] Toner FillUP *EGB Fills up the yellow toner.
9910 020 Upper Limit *EGB
Specifies the threshold for completing the toner
filled up. When the toner is detected three times, the
filling up the toner ends.
[0 to 5/ 3 / 1 /step]
9910 021 MUSIC Vsg Adj. *EGB
Selects the Vsg adjustment execution when the line
position adjustment is manually done.
5. Service Tables