SERVICE MODE TABLE
G104 5-28 SM
2181 033 [Y]: M. Scan Erro. *EGB
2181 034 [Y]: S. Scan Erro. *EGB
2181 035 [Y]: M Cor.: Dot *EGB [-127 to 127 / 0 / 1 dot/step]
2181 036 [Y]: M Cor.: SubD.. *EGB [-15 to 15 / 0 / 1 sub-dot/step]
2181 037 [Y]: S Cor.: 600 *EGB [-127 to 127 / 0 / 1 line/step]
2181 038 [Y]: S Cor.: 1200 *EGB [-127 to 127 / 0 / 1/step]
[MUSIC Record] Automatic Line Position Adjustment Record
2186
The following SPs display the MUSIC record.
2186 001 Year *EGB [0 to 99 / 0 / 1 y/step]
2186 002 Month *EGB [1 to 12 / 1 / 1 m/step]
2186 003 Date *EGB [1 to 31 / 1 / 1 d/step]
2186 004 Time *EGB [0 to 23 / 0 / 1 h/step]
2186 005 Minute *EGB [0 to 59 / 0 / 1 y/step]
2186 006 Temperature *EGB
[0 to 100 / 0 / 1°C/step]
2186 007 Result *EGB [0 to 999999 / 0 / 1 /step]
2186 008 Execution *EGB [0 to 9999 / 0 / 1 /step]
2186 009 Failure *EGB [0 to 9999 / 0 / 1 /step]
[Charge Bias: DC] Charge Roller Voltage: DC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
2201
These SPs adjust the DC voltage of the drum charge roller. These are used only
when SP3-501-001 is set to “1”.
2201 001 RS: [K] *EGB
2201 002 RS: [M] *EGB
2201 003 RS: [C] *EGB
2201 004 RS: [Y] *EGB
2201 006 LS: [K] *EGB
2201 007 LS: [M] *EGB
2201 008 LS: [C] *EGB
2201 009 LS: [Y] *EGB
[200 to 999 / 585 / 1 V/step]
[Charge Bias: AC] Charge Roller Voltage: AC
(Process Speed, [Color]) Process Speed -> LS: Low speed, RS: Regular speed
2202
These SPs adjust the AC voltage of the drum charge roller. These are used only
when SP2-202-011 is set to “1”.
2202 001 RS: [K] *EGB
2202 002 RS: [M] *EGB
2202 003 RS: [C] *EGB
2202 004 RS: [Y] *EGB
2202 006 LS: [K] *EGB
2202 007 LS: [M] *EGB
2202 008 LS: [C] *EGB
2202 009 LS: [Y] *EGB
[0 to 3000 / 2000 / 1 V/step]
2202 011 Output Control *EGB [0 or 1 / 0 / -]
0: Process Control, 1: Setting