SERVICE MODE TABLE
SM 5-31 G104
Service
Tables
2326
[T.Roll2 Clean.] Transfer Roller Cleaning
(Positive or Negative Bias, Process Speed) Process Speed -> RS: Regular
speed, LS: Low speed
2326 002 Posi. Bias: RS *EGB
2326 003 Posi. Bias: LS *EGB
Adjusts the positive voltage for transfer roller
cleaning.
[0 to 2 / 2.0 / 0.1 KV/step]
2326 005 Nega. Bias: RS *EGB
2326 006 Nega. Bias: LS *EGB
Adjusts the negative voltage for transfer
roller cleaning.
[0 to 60 / 60.0 / 0.1V/step]
2352
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> RS: Regular speed
2352 001 [K]: RS
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / 15.0 / 0.1 µA/step]
2353
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> LS: Low speed
2353 001 [K]: LS *EGB
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / 6.0 / 0.1 µA/step]
2357
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> RS: Regular speed
2357 001 [FC/ K]: RS *EGB
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / 15.0 / 0.1 µA/step]
2357 002 [FC/ M]: RS *EGB
2357 003 [FC/ C]: RS *EGB
2357 004 [FC/ Y]: RS *EGB
[0 to 60 / 12.5 / 0.1 µA/step]
2358
[Trans.Belt Bias] Transfer Belt Current
([Color], Process Speed) Process Speed -> LS: Low speed
2358 001 [FC/ K]: LS *EGB
2358 002 [FC/ M]: LS *EGB
2358 003 [FC/ C]: LS *EGB
2358 004 [FC/ Y]: LS *EGB
Adjusts the current that is applied to the
transfer belt.
[0 to 60 / 6.0 / 0.1 µA/step]
2402
[Normal: [K]] Transfer roller current and discharge plate voltage for the image
area, plain paper 1, black toner
(Process Speed, Paper Side, Unit) Process Speed -> RS: Regular speed,
Paper Side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separa.: Discharge plate (paper separation)
2402 007 RS: 1st: T. Roll2 *EGB Adjusts the transfer roller current.
[0 to 60 / 25.0 / 0.1 -µA/step]
2402 008 RS: 1st: Separa. *EGB Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
CÓPIA NÃO CONTROLADA