SERVICE MODE TABLE
SM 5-33 G104
Service
Tables
2422
[Switch Timing] Switch timing from leading edge to normal, plain paper 1
(Paper Type, Edge) Paper Type -> N: Normal LE: Leading Edge
2422 002 T. Roll 2: N: LE *EGB [0 to 200 / 10 / 1 mm/step]
2422 003 Separation: N: LE *EGB [0 to 200 / 25 / 1 mm/step]
2423
[Normal: [K]: TE] Transfer roller current and discharge plate voltage for the
trailing edge area, plain paper 1, black toner
Paper side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separation: Discharge plate (paper separation)
2423 003 Separation *EGB
2423 007 T. Roll 2: 1st *EGB
2423 012 T. Roll 2: 2nd *EGB
[0 to 400 / 100 / 5%/step]
2424
[Switch Timing] Switch timing from normal to trailing edge, plain paper 1
(Paper Type, Edge) Paper Type -> N: Normal, Edge ->TE: Trailing Edge
2424 002 T. Roll 2: N: TE *EGB [0 to 200 / 10 / 1 mm/step]
2424 003 Separation: N: TE *EGB [0 to 200 / 30 / 1 mm/step]
2426
[Normal: [FC]: LE] Transfer roller current and discharge plate voltage for the
leading edge area, plain paper 1, CMY toner
Paper side: 1st or 2nd
2426 003 Separation *EGB
2426 007 T. Roll 2: 1st *EGB
2426 012 T. Roll 2: 2nd *EGB
[0 to 400 / 100 / 5%/step]
2428
[Normal: [FC]: TE] Transfer roller current and discharge plate voltage for the
trailing edge area, plain paper 1, CMY toner
2428 003 Separation *EGB
2428 007 T. Roll 2: 1st *EGB
2428 012 T. Roll 2: 2nd *EGB
[0 to 400 / 100 / 5%/step]
2432
[Normal2: [K]] Transfer roller current and discharge plate voltage for the image
area, plain paper 2, black toner
(Process Speed, Paper Side, Unit) Process Speed -> RS: Regular speed,
Paper Side: 1st or 2nd
Unit -> T.Roll2: Transfer roller, Separa.: Discharge plate (paper separation)
2432 007 RS: 1st: T. Roll 2 *EGB Adjusts the transfer roller current.
[0 to 60 / 20.0 / 0.1 -µA/step]
2432 008 RS: 1st: Separa. *EGB Adjusts the discharge plate voltage.
[0 to 4 / 2.0 / 0.1 -KV/step]
2432 012 RS: 2nd: T. Roll 2 *EGB
[0 to 60 / 10.0 / 0.1 -µA/step]
2432 013 RS: 2nd: Separa. *EGB [0 to 4 / 2.0 / 0.1 -KV/step]